We will never lay over old felt. You'll be surprised how many "Quality" companies do that.
At RDZ ROOFING, we believe in taking a personalized approach to every project we undertake.
The roofing market is saturated with door knockers, wrapped trucks, silver-tongued salesmen and weasels. You deal with me, not the "office".
Roofing is easy, especially if you do it right.
We specialize in repairing all types of roof damage, including leaks, missing shingles, and storm damage. Our team will work efficiently to ensure your roof is back to its best condition.
If your roof is beyond repair, we offer complete roof replacement services. We only use high-quality materials and the latest techniques to ensure a durable and attractive roof for your home. We don't use 3 tab as hip and ridge shingles.
Best prices with quality product in town.
Regular inspections are key to catching problems before they're problems.
We offer a comprehensive inspection to identify any issues and recommend the best course of action. We provide pictures along with highlighted notation with every assessment so we can put your eyes on it. We will reseal any exposed seals. We will reseal up to 20 shingles.
$80 per roof inspection + report.
We begin with an assessment of the roof and of any collateral damage to the property. We help file the claim on the spot. We go over the insurance process with you every step of the way. We make it easy at RDZ.
If you have a 🌳 there's 🍃 🍂 🍁. We clean out the debris and let that water flow away from the house.
$8 per Linear feet.
- $20 per panel.
- $25 per panel, 2 story.
Ridge vent, not every roof system allows for it.
We run our formula (1:300) on the attic space to make sure that the roof has the proper ventilation needed to have a quality life.
"If it's too hot, your roof will rot."
This exhaust system is ideal for Hipped Roof Systems. Turtle Vents are static, they have no moving parts.
Allows the roof to breathe properly on larger hipped roofs.
2 slant back / turtle vents = 1 Dish Vent.
The vents rely on wind to circulate the air in your attic. Wind Turbine vents are efficient. They are not pleasing to the eye as they sit about a foot and a half off of the roof and the moving parts are exposed to the elements. When it stops spinning your roof is not winning.
Gable Vents ventilate your roof without being on your roof. When the wind blows, the vents allow the air to flow out throughthe attic.
Having both exhaust systems on the roof will not vent the roof system properly (Short Circut).
A five-year-old roof can look like this, having aged at an accelerated rate due to the lack of air flow.
Is it enough space for your roof to breathe?
We calculate attic floor. (L x W = SQ FT)
SQ. FT. / 300 = NET FREE VENT AREA
SQ. FT X 144 = SQ. IN.
NFVA = SQ. IN. / 2
SQ. IN. INTAKE / SQ IN. EXHAUST